Advertise with us
Medical Group

Global Journal of Anesthesiology

ISSN: 2455-3476

DOI

CC By

Abstract Open Access
Case Report PTZAID: GJA-2-119

Placenta Previa Combined with Placenta Accreta and Fetal Congenital High Airway Obstruction- Failed Ex Utero Intrapartum Treatment

Sohan Lal Solanki*, Gautam Chand Bhansali

A parturient with placenta previa and accreta combined with fetal congenital high airway obstruction was scheduled for cesarean section. Ex utero intrapartum (EXIT) treatment on fetus after classical cesarean section was planned. General anesthesia was induced after routine and invasive haemodynamic monitoring started. Profuse bleeding was started as soon as the baby was delivered. EXIT procedure was cancelled and cord was clamped and cut. ENT surgeon performed tracheostomy on baby and airway was secured but baby died after half an hour. Emergency cesarean hysterectomy was done after all measures to control the bleeding were failed.

Published on: Dec 10, 2015 Pages: 57-59

Full Text PDF Full Text HTML DOI: 10.17352/2455-3476.000019